Products Description
Application:
Features && Specification
Installing an eccentric reducer on a pump: This is done to prevent cavitation. Generally, the reducer at the pump inlet should be installed with the top flush with the surface. This prevents vapor from accumulating at the pump inlet, forming large bubbles that enter the pump chamber and damage the pump. There is only one scenario where bottom-flush installation is permitted: when the reducer is directly connected to an upward-curving elbow. In this case, vapor cannot accumulate.
2. Pump-Pipeline Installation of Reducers: When there is a size difference between the pump outlet and the external piping system, reducers are used to achieve a straight connection between two pipes of different sizes, serving as fittings for pipe diameter transitions.
Axial displacement of an eccentric rubber reducer refers to the elongation or compression of the rubber reducer in the direction of fluid flow (i.e., along the central axis).
Material of each components
| No. | Part | Material |
| 1 | Body | NR, CR, IIR), NBR, FKM, EPDM |
| 2 | Inner & Outer Rubber | NR, CR, IIR, NBR, FKM, EPDM, PTFE |
| 3 | Body Carcass | Nylon cord fabric |
| 4 | Reinforcing Ring | Multi-strand coppering steel wire |
| 5 | 法兰 Flange | Cast and forged carbon steel Q235, Stainless steel(201, 304, 316, 321), Plastic(CPVC, PVDF, PPH, UPVC, RPP) |
Technical arameters
| Item |Medol | KYT(DN50~300) | KYT(DN350~600) | A. If media is oil, acid or alkali. B. If special requirements for working temperature C. If OEM orders with drawings or samples D. Please Inform us about above when ordering |
|
| Woring pressure Mpa | 1.0 | 0.6 | ||
| Burst Pressure Mpa | 1.8 | 1.5 | ||
| Vacuum Kpa | 86.7 | 53.3 | ||
| Applicable Temperature | -20℃~+115℃(-30℃~+250℃ under special conditions) | |||
| Applicable Medium | Air, compressed air, water, sea water, oil, acid, alkali, etc. | |||
| Note: the materials of main parts are the same with those of KXT type | ||||
Main date
| Nominal Diameter (mm) |
LengthL(mm) | Axial displacement (mm) | Haorizontal isplacement(mm) | Angular deflection(a1+a2)° | |
|
伸长Extension |
压缩Compression |
||||
| 40×25 | 115 | 7 | 12 | 10 | 10 |
| 40×32 | 125 | 7 | 12 | 10 | 10 |
| 50×40 | 180 | 7 | 12 | 10 | 10 |
| 65×40 | 180 | 7 | 12 | 10 | 10 |
| 65×50 | 180 | 7 | 12 | 10 | 10 |
| 80×50 | 180 | 7 | 12 | 10 | 10 |
| 80×65 | 180 | 7 | 12 | 10 | 10 |
| 100×50 | 180 | 7 | 12 | 10 | 10 |
| 100×65 | 180 | 7 | 12 | 10 | 10 |
| 100×80 | 180 | 8 | 14 | 12 | 10 |
| 125×65 | 200 | 8 | 14 | 12 | 10 |
| 125×80 | 200 | 8 | 14 | 12 | 10 |
| 125×100 | 200 | 10 | 20 | 12 | 10 |
| 150×50 | 200 | 10 | 20 | 12 | 10 |
| 150×65 | 200 | 10 | 20 | 12 | 10 |
| 150×80 | 200 | 10 | 20 | 12 | 10 |
| 150×100 | 200 | 10 | 20 | 12 | 10 |
| 150×125 | 200 | 12 | 20 | 14 | 10 |
| 200×80 | 200 | 12 | 20 | 14 | 10 |
| 200×100 | 200 | 12 | 20 | 14 | 10 |
| 200×125 | 200 | 12 | 20 | 14 | 10 |
| 200×150 | 200 | 12 | 20 | 14 | 10 |
| 250×125 | 220 | 12 | 20 | 14 | 10 |
| 250×150 | 220 | 12 | 20 | 14 | 10 |
| 250×200 | 220 | 12 | 20 | 20 | 10 |
| 300×125 | 220 | 14 | 22 | 20 | 10 |
| 300×150 | 220 | 14 | 22 | 20 | 10 |
| 300×200 | 220 | 14 | 22 | 20 | 10 |
| 300×250 | 220 | 14 | 22 | 20 | 10 |
| 350×150 | 240 | 14 | 22 | 20 | 10 |
| 350×200 | 240 | 14 | 22 | 20 | 10 |
| 350×250 | 240 | 14 | 22 | 20 | 10 |
| 350×300 | 240 | 14 | 22 | 20 | 10 |
| 400×200 | 240 | 14 | 22 | 20 | 10 |
| 400×250 | 240 | 14 | 22 | 20 | 10 |
| 400×300 | 240 | 14 | 22 | 20 | 10 |
| 400×350 | 240 | 14 | 22 | 20 | 10 |
| 450×300 | 240 | 14 | 22 | 20 | 10 |
| 450×350 | 240 | 14 | 22 | 20 | 10 |
| 450×400 | 240 | 14 | 22 | 20 | 10 |
| 500×350 | 240 | 14 | 22 | 20 | 10 |
| 500×400 | 240 | 14 | 22 | 20 | 10 |
| 500×450 | 240 | 14 | 22 | 20 | 10 |
| Notes:1. For OEM orders with special requirement, rubber joints can be made according to customers' drawings. Material of rubber body can be NR natural rubber, EPDM, Neoprene, IIR butyl rubber, NBR Buna-N, FKM, etc. 2.When rubber joints size above DN200 are used for overhead water supply system, the pipes must be equipped with fixed supports or fixed brackets, otherwise control units shall be installed on rubber joints. |
|||||